Pressure defoaming oven

Time:2026/11/9 17:27:36Clicks:59

Suitable for: (Customization supported) PCB, FPC, TP, Optoelectronics (LED/LCD), New Energy, Chips, Semiconductors, Integrated Circuits, Thin Film Buttons, Camera, Mobile Phone, Communication, Hardware, Plastic, Touch Screen, Computer, Display, Capacitor IC、 Electronic components, new materials, chemicals, electronic components, lenses, cameras, module dispensing, post printing curing, and drying and baking of products in various industries such as IC, IGBT, lithium batteries, wafers, crystal oscillators, battery electrodes, connectors, and medical products.

Item No.

Category

Specifications

1

Scope of Application

Special-purpose model for high-temperature curing and bubble removal after die bonding and dispensing in industries such as wafer and semiconductor packaging.

2

Power

Total Equipment Power

7KVA

Power Supply

AC380V  3φ  50HZ  

Internal Dimensions

Pressure Tank Dimensions

Diameter 600×D600mm

Product Placement Area

W420*D600*H420mm

External Dimensions

W1380mm×D1600mm×1540mm (Reference Dimensions)

4

Equipment Structure

1. Single-chamber cylindrical structure design; the electrical control cabinet is located on the right side of the machine.

2. A sheathed electric heater is used to circulate-heat the slightly pressurized gas circulating inside the chamber; forced pressurization outside the chamber and automatic circulating pressure relief complete the air-exchange function and discharge exhaust gas, so as to keep the chamber pressure relatively higher than the external pressure. When the gas temperature inside the chamber reaches the set value, the heater automatically stops heating; when the chamber temperature falls below the set value, the heater automatically restarts, so as to keep the chamber temperature stable!

3. Vertical type; the fan is located at the rear of the cabinet and supplies air horizontally.

6. One set of heating control; the heater and hot-air circulation system are located at the rear of the cabinet.

7. Circulating fan power 750W, 1 unit.

5

Materials and Standards

1. The interior is made of SUS304# 5.0mm stainless steel plate with concave iron reinforcement.

2. The exterior is made of SUS41# cold-rolled steel plate with anti-static powder coating, wrinkle beige.

3. High-grade insulation cotton is used; insulation layer thickness 90 mm, with a heat insulation plate.

4. High-temperature-resistant silicone gasket is used; temperature resistance ≥260°C.

5. Heavy-duty rotary door latch with adjustable American-style hinge.

 

6

Pressurized System

1. Positive-pressure structural design; the chamber can withstand 8 kg of positive pressure.

2. Equipped with a pressure regulating valve, pressure relief valve, digital pressure gauge, and gas pressure protection; high-pressure alarm and scheduled start/stop functions.

3. Safety door protection: pressurization is impossible if the door is not tightly closed, and the door cannot be opened until the chamber pressure returns to normal pressure; combination of manual and automatic pressure relief.

7

Negative-Pressure (Vacuum) System

Vacuum range: −0.090~0.1MPa

Pumping rate: 8L/S.

Vacuum degree ≤133pa

Leak rate ≤0.001pa/L/S

6

Temperature Parameters

Temperature Range

Room Temperature~250°C

Heating Rate

≥8°C/min

Over-Temperature Control

XZ-480 Over-Temperature Protector

Sensor Temperature Accuracy

±0.3°C

Uniformity

±2%°C

Cooling Rate

200°C→60°C≥6°C/min

Cooling Rate

At the commonly used 200°C, [the temperature] is ≤ room temperature + 10°C, except at the four edges of the oven door and the exhaust port.

7

Temperature Control System

a. Operated via a 7-inch touch screen, TFT LCD display, 1024*600 resolution, universal sensor input, 100ms sampling period, imported PID module, 0.1% control accuracy.

b. Paperless recording function; records 120 days of data and can directly export temperature curves.

c. R232 communication, remote monitoring function.

d. Digital setting, cut-off temperature, constant-temperature timing alarm, over-temperature alarm and other functions. One set of over-temperature alarm per chamber.

e. 9999 timer; signal source: imported CA sensing rod ±0.5%. Controlled output component: SSR contactless signal output.

8

Circulating Air System

Special air-path design for uniform heating temperature.

Uses a long-shaft motor dedicated to hot-air ovens.

Uses a heavy-duty stainless steel impeller.

9

Nitrogen System

Gas inlet: equipped with an N2 flow meter to control the intake volume. Inlet port: 12mm.

Gas inlet: Air Ø1/2” or N2 Ø1/2”; automatic intake/exhaust port: Ø3/4”.

Nitrogen concentration: 99.99%.

Oxygen content ≤100ppm.

10

Safety Pressure Protection

1. Equipped with a pressure regulating valve, pressure relief valve, digital pressure gauge, and a scheduled start/stop function.

2. Equipped with a scheduled exhaust function.

3. Equipped with gas pressure protection and high/low pressure alarm.

4. Safety door protection: pressurization is impossible if the door is not tightly closed, and the door cannot be opened until the chamber pressure returns to normal pressure.

5. Combination of manual and automatic pressure relief.

9

Electrical Safety Protection

1. Motor over-current protection, phase-sequence protector, leakage protector, control-circuit fuse, no-fuse breaker, and contactor accessories all use Class-1 products conforming to national standards.

2. Features an upper-limit over-temperature alarm function and a temperature/time holding function.

3. The motor can be set to continue supplying air after heating is cut off at the end of the constant-temperature period.

10

Applicable Standards

Test Methods for Electric Heating Equipment of the People‘s Republic of China GB/T10066-2004, JB20033-2004, and Safety of Electric Heating Installations GB5959.1-2005, GB150-1998 Steel Pressure Vessels

11

Internal Devices

Stainless steel finned heater

12

External Devices

1. Air inlet, air outlet, American-style hinge, rotary heavy-duty door latch, and four transport wheels installed.

2. The exhaust port is located at the top of the cabinet, with an adjustable opening size.

13

Equipped

1. A 3m power cord is supplied with the machine.

2. Equipped with a volatile-substance treatment device to reduce volatile deposits and lower cleaning/maintenance effort.

3. Equipped with a circulating water-cooling device.

14

Warranty

One-year free replacement/repair service for faulty parts after delivery.

15

Main Components

 

Details of Some Parts

Item No.

Name

Specification/Model

Brand

Origin or Manufacturer

1

Motor

1/2HP

Jiacheng

Taiwan

2

Touch Screen

7-inch

Weintek

Taiwan

3

Temperature Module

 

Siemens

Germany

 

PLC

 

Siemens

Germany

4

Power Supply

 

MEAN WELL

Taiwan

5

SSR

25A

Xuanrong

Taiwan

6

Over-Temperature Limit

XZ-480

Xinzhou

Dongguan

7

Heater

XZ-A-12-300

Xinzhou

Dongguan

8

Temperature Sensor

Type K

Minyang

Taiwan

9

Intermediate Relay

MY-4NJ

OMRON

Japan

10

Phase-Sequence Protector

XJ3-S

Feinade

Zhejiang

11

Overload Protector

 

Schneider

Shanghai

12

Leakage Protector

 

Schneider

Shanghai

13

Contactor

0810

Schneider

Shanghai

14

Digital Pressure Gauge

 

SMC

Japan

15

Pressure Relief Valve

 

AirTAC

Taiwan

16

High-Temperature Vacuum Valve

25mm

Keben

Shanghai

17

Vacuum Pump

VSV

Feiyue

Zhejiang

 

+86 191-6892-5687